Federal Register: HHS Rules · September 11, 2026

Medical Devices; Cardiovascular Devices; Classification of the Cardiovascular Machine Learning-Based Notification Software

Score 40Agency RuleFederal Register

What the document says

FDA issued a final order on September 11, 2026, classifying cardiovascular machine learning-based notification software into class II (special controls) under 21 CFR Part 870, adding new section 870.2380. The classification was made effective September 11, 2026, with applicability retroactive to August 3, 2023, the date FDA issued its original order to the De Novo requester, Viz.ai, Inc., regarding its Viz HCM device. The device is defined as software that employs machine learning techniques to suggest the likelihood of a cardiovascular disease or condition for further referral or diagnostic follow-up, identifying a single condition from one or more non-invasive physiological inputs during routine medical care. The software is not intended to provide diagnostic quality output and is not intended to identify or detect arrhythmias. FDA received Viz.ai, Inc.'s De Novo classification request on January 10, 2023, under section 513(f)(2) of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. 360c(f)(2)). The De Novo process was used because the device, as a postamendments device not in commercial distribution before May 28, 1976, was automatically assigned to class III under 21 U.S.C. 360c(f)(1). FDA determined that class II classification with special controls, in combination with general controls, provides reasonable assurance of safety and effectiveness, avoiding the premarket approval requirement that applies to class III devices. The identified risks to health include false positive or false negative outputs leading to incorrect treatment or diagnosis, model bias or failure to generalize to the intended use population, use in unsupported patient populations or with unsupported hardware, and overreliance on device output. FDA identified clinical performance testing, non-clinical performance testing, software verification and validation, human factors assessment, and labeling as the required mitigation measures for these risks. The special controls codified at 21 CFR 870.2380(b) require, among other things, clinical validation using a test dataset of real-world data from a representative patient population with a minimum of three geographically diverse sites separate from training sites, subgroup analyses across demographic populations and acquisition systems, software verification and validation including hazard analysis and integration testing, human factors assessment evaluating the risk of misinterpretation of device output, and labeling that includes performance testing summaries, device limitations, and warnings against using device output as a sole basis for further testing. The device remains subject to premarket notification requirements under section 510(k) of the FD&C Act, as FDA has not exempted it under section 510(m). Because it is now a De Novo-classified device, it serves as a predicate for future substantially equivalent devices.

What this may mean

Applies to manufacturers of cardiovascular machine learning-based notification software, who must comply with the special controls at 21 CFR 870.2380(b) and submit a 510(k) premarket notification to market devices of this type. The classification takes effect September 11, 2026, with applicability from August 3, 2023. Future sponsors of substantially equivalent devices may use the 510(k) pathway rather than a De Novo request or premarket approval application.

Informational only. Not legal, medical, financial, or other professional advice. Always consult a qualified professional familiar with your specific facts before relying on any item.

Related items